OB100 Startup : Supervisory Control and Data Acquisition |
|
|
|
|
|
Network 1: P01 Plant Info SCADA "HMI KEY".PlantInfo.Pallet_A.Code := DW#16#CEA_0000; "HMI KEY".PlantInfo.Pallet_A.Layer := 2; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.Reference_Pos[1] := 756.46; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.Reference_Pos[2] := 843.53; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.Reference_Pos[3] := 850.0; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.Reference_Pos[4] := 0.0; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.Gap_X := 0.0; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.Gap_Y := 54.42; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.Gap_Z := 20.0; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.PlacesOn_X := 1; "HMI KEY".PlantInfo.Pallet_A.Layer_Data.PlacesOn_Y := 5; "HMI KEY".PlantInfo.Pallet_A.Places := "HMI KEY".PlantInfo.Pallet_A.Layer_Data.PlacesOn_X * "HMI KEY".PlantInfo.Pallet_A.Layer_Data.PlacesOn_Y; "HMI KEY".PlantInfo.Pallet_A.Distance_to_LayerTop := 130.0; // 850.0 - 720.0 "HMI KEY".PlantInfo.Pallet_A.Layer_Data.MOD_Y := TRUE; // ---- "HMI KEY".PlantInfo.Pallet_B.Code := DW#16#CEA_0000; "HMI KEY".PlantInfo.Pallet_B.Layer := 3; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.Reference_Pos[1] := 756.46; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.Reference_Pos[2] := 185.0; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.Reference_Pos[3] := 850.0; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.Reference_Pos[4] := 0.0; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.Gap_X := 0.0; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.Gap_Y := 65.30; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.Gap_Z := 25.0; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.PlacesOn_X := 1; "HMI KEY".PlantInfo.Pallet_B.Layer_Data.PlacesOn_Y := 4; "HMI KEY".PlantInfo.Pallet_B.Places := "HMI KEY".PlantInfo.Pallet_B.Layer_Data.PlacesOn_X * "HMI KEY".PlantInfo.Pallet_B.Layer_Data.PlacesOn_Y; "HMI KEY".PlantInfo.Pallet_B.Distance_to_LayerTop := 125.0; // 850.0 - 725.0 "HMI KEY".PlantInfo.Pallet_B.Layer_Data.MOD_Y := TRUE; "HMI KEY".PlantInfo.Pick_Distance_to_ConveyorBelt := 100.0; // SET Base Positions of Delta Picker in (WCS) "HMI KEY".PlantInfo.MoveLinear_WCS[0].Axis[1] := 756.46; "HMI KEY".PlantInfo.MoveLinear_WCS[0].Axis[2] := 609.52; "HMI KEY".PlantInfo.MoveLinear_WCS[0].Axis[3] := 800.0; // 850.0; 03022026 "HMI KEY".PlantInfo.MoveLinear_WCS[0].Axis[4] := 0.0; // SEQ1 Delta Picker 3D MoveLinearAbsolute OCS1 DOWN "HMI KEY".PlantInfo.MoveLinear_WCS[1].Axis[1] := 0.0; "HMI KEY".PlantInfo.MoveLinear_WCS[1].Axis[2] := 0.0; "HMI KEY".PlantInfo.MoveLinear_WCS[1].Axis[3] := 20.0; // DOWN to PICK UP (min. Product height) "HMI KEY".PlantInfo.MoveLinear_WCS[1].Axis[4] := 0.0; // SEQ1 Delta Picker 3D MoveLinearAbsolute OCS1 FOLLW to PICK UP "HMI KEY".PlantInfo.MoveLinear_WCS[2].Axis[1] := 120.0; // --> "HMI KEY".PlantInfo.MoveLinear_WCS[2].Axis[2] := 0.0; "HMI KEY".PlantInfo.MoveLinear_WCS[2].Axis[3] := 0.0; "HMI KEY".PlantInfo.MoveLinear_WCS[2].Axis[4] := 0.0; // Velocity "HMI KEY".PlantInfo.Slow_Velocity := 30.0; "HMI KEY".PlantInfo.Work_Velocity := 70.0; "HMI KEY".PlantInfo.Window := 5.0; |
|