OB1 Main Main Program Sweep

 

 

 

Network 1: Start measuring runtime (Start Cycle)

    "HMI SYS".Support.LastCycle := RUNTIME("HMI SYS".Support.LastCycle_inout);

 

 

 

Network 2: Pulse generator

    "HMI SYS".Support.Sav_Clock_Byte := "HMI SYS".Support.Sav_Clock_Byte XOR "M01 Clock_Byte";

    "M00 PLC Impulse" := "HMI SYS".Support.Sav_Clock_Byte AND "Clock_Byte";

    "HMI SYS".Support.Sav_Clock_Byte := "M01 Clock_Byte";

 

 

 

Network 3: CALL distributor

-> "DI MAIN GLB"(); // or click Log-In

-> "DI MAIN P01"(); // Process01, main module function block

-> "DI OUT P01"()// Process01, execute output stage

 

 

 

Network 4: First cycle evaluation

"HMI SYS".Support.FirstCycle_TON(IN := TRUE,PT := t#2s);

"M00 OB1 FirstCycle" := "HMI SYS".Support.FirstCycle_TON.Q;

 

 

 

Network 5: Flag logic =0

    "M00 log 0" := FALSE;

    "M00 log 1" := TRUE;

 

 

 

Network 6: End measuring runtime (End Cycle)

"HMI SYS".Support.LastCycle_real := LREAL_TO_REAL(IN := RUNTIME("HMI SYS".Support.LastCycle_inout) * 1000.0);

 

 