FB69 OUT P04 : Spring winding inspection - outputs (slave 4)

[hit  <- on your browser to return]

 

 

 

Netzwerk 1: Call manual operation

 

#MANUAL(ST_MANU := "M00 ManuCmpltMa run",

        MODULE_HP := "HMI KEY".P04.GLB.F20_HomPos,

        SUPPORT_SEQ := "M04 RunHomPos");

 

 

 

Netzwerk 2: Pre-Setting

 

 

 

 

 

Netzwerk 3: G04 Clamp cylinder

 

#G04(CMD_WP := FALSE,

     CMD_HP := FALSE,

     FB_WP := "E04 G04 WP",

     FB_HP := "E04 G04 HP",

     RLS := "E00 Y56 WP",

     ACK_FLT := "M00 ACK Imp",

     VALV_WP => "A04 G04 WP",

     VALV_HP => "A04 G04 HP");

 

 

 

Netzwerk 4: Z05 Rotary cylinder

 

#Z05(CMD_WP := FALSE,

     CMD_HP := FALSE,

     FB_WP := "E04 Z05 WP",

     FB_HP := "E04 Z05 HP",

     RLS := "E00 Y56 WP",

     ACK_FLT := "M00 ACK Imp",

     VALV_WP => "A04 Z05 WP",

     VALV_HP => "A04 Z05 HP");

 

 

 

Netzwerk 5: Z06 Lift cylinder

 

#Z06(CMD_WP := FALSE,

     CMD_HP := FALSE,

     FB_WP := "E04 Z06 WP",

     FB_HP := "E04 Z06 HP",

     RLS := "E00 Y56 WP",

     ACK_FLT := "M00 ACK Imp",

     VALV_WP => "A04 Z06 WP",

     VALV_HP => "A04 Z06 HP");

 

 

 

Netzwerk 6: Z07 Lift lock-out cylinder

 

#Z07(CMD_WP := FALSE,

     CMD_HP := FALSE,

     FB_WP := "E04 Z07 WP",

     FB_HP := "E04 Z07 HP",

     RLS := "E00 Y56 WP",

     ACK_FLT := "M00 ACK Imp",

     VALV_WP => "A04 Z07 WP",

     VALV_HP => "A04 Z07 HP");

 

 

 

Netzwerk 7: CAM2 Spring winding inspection

 

#CAM2(ixTrigger := #CAM2_IO.IN.ixTrigger,

      ixChApp := #CAM2_IO.IN.ixChApp,

      iiAppNo := #CAM2_IO.IN.iiAppNo,

      oxBusy => #CAM2_IO.OUT.oxBusy,

      oxDone => #CAM2_IO.OUT.oxDone,

      oxError => #CAM2_IO.OUT.oxError,

      owStatus => #CAM2_IO.OUT.owStatus,

      oiActAppNo => #CAM2_IO.OUT.oiActAppNo,

      odiRcvdLen => #CAM2_IO.OUT.odiRcvdLen,

      ioudtCfgData := #CAM2_IO.IN_OUT);