FB49 OUT P02 : Material Handling (Box transport) |
|
|
|
Netzwerk 1: Pre-Setting #tmp_operation_mode := "DI MAIN GLB".M00.AutoCmpltMa_run OR "DI MAIN P03".M00.HomPosRun; |
|
|
|
Netzwerk 2: Call manual operation #Manual(ST_MANU := "DI MAIN GLB".M00.ManuCmpltMa_run, MODULE_HP := "HMI KEY".P02.GLB.F20_HomPos, SUPPORT_SEQ := "DI MAIN P02".M00.HomPosRun); |
|
|
|
Netzwerk 3: M201 Box Infeed Conveyor #M201(CMD_ONOFF := #M201.DRV.ActorJog_WP, FD_BACK := "E00 M201 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M201 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M201 CW"); |
|
|
|
Netzwerk 4: M202 Box Supply Conveyor #M202(CMD_ONOFF := #M202.DRV.ActorJog_WP, FD_BACK := "E00 M202 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M202 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M202 CW"); |
|
|
|
Netzwerk 5: M203 Box Outfeed Conveyor #M203(CMD_ONOFF := #M203.DRV.ActorJog_WP, FD_BACK := "E00 M203 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M203 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M203 CW"); |
|
|
|
Netzwerk 6: M204 Box Infeed Conveyor HSB #M204(CMD_ONOFF := #M204.DRV.ActorJog_WP, FD_BACK := "E00 M204 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M204 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M204 CW"); |
|
|
|
Netzwerk 7: M205 Box Infeed Conveyor STC #M205(CMD_ONOFF := #M205.DRV.ActorJog_WP, FD_BACK := "E00 M205 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M205 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M205 CW"); |
|
|
|
Netzwerk 8: M206 Box Outfeed Conveyor STC #M206(CMD_ONOFF := #M206.DRV.ActorJog_WP, FD_BACK := "E00 M206 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M206 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M206 CW"); |
|
|
|
Netzwerk 9: M207 Box Outfeed Coveyor HSB #M207(CMD_ONOFF := #M207.DRV.ActorJog_WP, FD_BACK := "E00 M207 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M207 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M207 CW"); |
|
|
|
Netzwerk 10: M208 Swivel Infeed Conveyor HBS #M208(CMD_ONOFF := #M208.DRV.ActorJog_WP, FD_BACK := "E00 M208 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M208 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M208 CW"); |
|
|
|
Netzwerk 11: M209 Swivel Outfeed Conveyor HBS #M209(CMD_ONOFF := #M209.DRV.ActorJog_WP, FD_BACK := "E00 M209 Fb", HALT_01 := NOT "E00 27S5 Estop", MCB := "E00 M209 MCB", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M209 CW"); |
|
|
|
Netzwerk 12: C201 HTU Box Outfeed HBS #C201(CMD_HP := FALSE, CMD_WP := FALSE, FB_HP := "E01 C201 HP", FB_WP := "E02 C201 WP", RLS := "E00 Air Pressure ok", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg, VALV_HP => "A02 C201 HP", VALV_WP => "A02 C201 WP"); |
|
|
|
Netzwerk 13: C202 HTU Box Infeed HBS #C202(CMD_HP := FALSE, CMD_WP := FALSE, FB_HP := "E02 C202 HP", FB_WP := "E02 C202 WP", RLS := "E00 Air Pressure ok", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg, VALV_HP => "A02 C202 HP", VALV_WP => "A02 C202 WP"); |
|
|
|
Netzwerk 14: C204 Swivel Infeed Cylinder HBS #C204(CMD_HP := FALSE, CMD_WP := FALSE, FB_HP := "E02 C204 HP", FB_WP := "E02 C204 WP", RLS := "E00 Air Pressure ok", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg, VALV_HP => "A02 C204 HP", VALV_WP => "A02 C204 WP"); |
|
|
|
Netzwerk 15: C206 Swivel Outfeed Cylinder HBS #C206(CMD_HP := FALSE, CMD_WP := FALSE, FB_HP := "E02 C206 HP", FB_WP := "E02 C206 WP", RLS := "E00 Air Pressure ok", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg, VALV_HP => "A02 C206 HP", VALV_WP => "A02 C206 WP"); |
|
|
|
Netzwerk 16: Y201 Box Infeed Stopper #Y201(CMD_WP := FALSE, FB_HP := NOT "A02 Y201 WP", FB_WP := "E02 Y201 WP", RLS := "E00 10F3 24V P02", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, VALV_WP => "A02 Y201 WP"); |
|
|
|
Netzwerk 17: Y202 Box Supply Stopper #Y202(CMD_WP := FALSE, FB_HP := NOT "A02 Y202 WP", FB_WP := "E02 Y202 WP", RLS := "E00 10F3 24V P02", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, VALV_WP => "A02 Y202 WP"); |
|
|
|
Netzwerk 18: Y204 Box Infeed Stopper HSB #Y204(CMD_WP := FALSE, FB_HP := NOT "A02 Y204 WP", FB_WP := "E02 Y204 WP", RLS := "E00 10F3 24V P02", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, VALV_WP => "A02 Y204 WP"); |
|
|
|
Netzwerk 19: Y205 Box Infeed Stopper STC #Y205(CMD_WP := FALSE, FB_HP := NOT "A02 Y205 WP", FB_WP := "E02 Y205 WP", RLS := "E00 10F3 24V P02", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, VALV_WP => "A02 Y205 WP"); |
|
|
|
Netzwerk 20: Y206 Box Outfeed Stopper HSB #Y206(CMD_WP := FALSE, FB_HP := NOT "A02 Y206 WP", FB_WP := "E02 Y206 WP", RLS := "E00 10F3 24V P02", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, VALV_WP => "A02 Y206 WP"); |
|
|
|
Netzwerk 21: Y207 Box Outfeed Stopper STC #Y207(CMD_WP := FALSE, FB_HP := NOT "A02 Y207 WP", FB_WP := "E02 Y207 WP", RLS := "E00 10F3 24V P02", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, VALV_WP => "A02 Y207 WP"); |
|