FB49 OUT P02 : Material Handling (Box transport)

[hit  <- on your browser to return]

 

 

 

Netzwerk 1: Pre-Setting

#tmp_operation_mode := "DI MAIN GLB".M00.AutoCmpltMa_run OR "DI MAIN P03".M00.HomPosRun;

 

 

 

Netzwerk 2: Call manual operation

#Manual(ST_MANU := "DI MAIN GLB".M00.ManuCmpltMa_run,

        MODULE_HP := "HMI KEY".P02.GLB.F20_HomPos,

        SUPPORT_SEQ := "DI MAIN P02".M00.HomPosRun);

 

 

 

Netzwerk 3: M201 Box Infeed Conveyor

#M201(CMD_ONOFF := #M201.DRV.ActorJog_WP,

      FD_BACK := "E00 M201 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M201 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M201 CW");

 

 

 

Netzwerk 4: M202 Box Supply Conveyor

#M202(CMD_ONOFF := #M202.DRV.ActorJog_WP,

      FD_BACK := "E00 M202 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M202 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M202 CW");

 

 

 

Netzwerk 5: M203 Box Outfeed Conveyor

#M203(CMD_ONOFF := #M203.DRV.ActorJog_WP,

      FD_BACK := "E00 M203 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M203 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M203 CW");

 

 

 

Netzwerk 6: M204 Box Infeed Conveyor HSB

#M204(CMD_ONOFF := #M204.DRV.ActorJog_WP,

      FD_BACK := "E00 M204 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M204 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M204 CW");

 

 

 

Netzwerk 7: M205 Box Infeed Conveyor STC

#M205(CMD_ONOFF := #M205.DRV.ActorJog_WP,

      FD_BACK := "E00 M205 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M205 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M205 CW");

 

 

 

Netzwerk 8: M206 Box Outfeed Conveyor STC

#M206(CMD_ONOFF := #M206.DRV.ActorJog_WP,

      FD_BACK := "E00 M206 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M206 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M206 CW");

 

 

 

Netzwerk 9: M207 Box Outfeed Coveyor HSB

#M207(CMD_ONOFF := #M207.DRV.ActorJog_WP,

      FD_BACK := "E00 M207 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M207 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M207 CW");

 

 

 

Netzwerk 10: M208 Swivel Infeed Conveyor HBS

#M208(CMD_ONOFF := #M208.DRV.ActorJog_WP,

      FD_BACK := "E00 M208 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M208 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M208 CW");

 

 

 

Netzwerk 11: M209 Swivel Outfeed Conveyor HBS

#M209(CMD_ONOFF := #M209.DRV.ActorJog_WP,

      FD_BACK := "E00 M209 Fb",

      HALT_01 := NOT "E00 27S5 Estop",

      MCB := "E00 M209 MCB",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M209 CW");

 

 

 

Netzwerk 12: C201 HTU Box Outfeed HBS

#C201(CMD_HP := FALSE,

      CMD_WP := FALSE,

      FB_HP := "E01 C201 HP",

      FB_WP := "E02 C201 WP",

      RLS := "E00 Air Pressure ok",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg,

      VALV_HP => "A02 C201 HP",

      VALV_WP => "A02 C201 WP");

 

 

 

Netzwerk 13: C202 HTU Box Infeed HBS

#C202(CMD_HP := FALSE,

      CMD_WP := FALSE,

      FB_HP := "E02 C202 HP",

      FB_WP := "E02 C202 WP",

      RLS := "E00 Air Pressure ok",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg,

      VALV_HP => "A02 C202 HP",

      VALV_WP => "A02 C202 WP");

 

 

 

Netzwerk 14: C204 Swivel Infeed Cylinder HBS

#C204(CMD_HP := FALSE,

      CMD_WP := FALSE,

      FB_HP := "E02 C204 HP",

      FB_WP := "E02 C204 WP",

      RLS := "E00 Air Pressure ok",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg,

      VALV_HP => "A02 C204 HP",

      VALV_WP => "A02 C204 WP");

 

 

 

Netzwerk 15: C206 Swivel Outfeed Cylinder HBS

#C206(CMD_HP := FALSE,

      CMD_WP := FALSE,

      FB_HP := "E02 C206 HP",

      FB_WP := "E02 C206 WP",

      RLS := "E00 Air Pressure ok",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_REg,

      VALV_HP => "A02 C206 HP",

      VALV_WP => "A02 C206 WP");

 

 

 

Netzwerk 16: Y201 Box Infeed Stopper

#Y201(CMD_WP := FALSE,

      FB_HP := NOT "A02 Y201 WP",

      FB_WP := "E02 Y201 WP",

      RLS := "E00 10F3 24V P02",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      VALV_WP => "A02 Y201 WP");

 

 

 

Netzwerk 17: Y202 Box Supply Stopper

#Y202(CMD_WP := FALSE,

      FB_HP := NOT "A02 Y202 WP",

      FB_WP := "E02 Y202 WP",

      RLS := "E00 10F3 24V P02",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      VALV_WP => "A02 Y202 WP");

 

 

 

Netzwerk 18: Y204 Box Infeed Stopper HSB

#Y204(CMD_WP := FALSE,

      FB_HP := NOT "A02 Y204 WP",

      FB_WP := "E02 Y204 WP",

      RLS := "E00 10F3 24V P02",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      VALV_WP => "A02 Y204 WP");

 

 

 

Netzwerk 19: Y205 Box Infeed Stopper STC

#Y205(CMD_WP := FALSE,

      FB_HP := NOT "A02 Y205 WP",

      FB_WP := "E02 Y205 WP",

      RLS := "E00 10F3 24V P02",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      VALV_WP => "A02 Y205 WP");

 

 

 

Netzwerk 20: Y206 Box Outfeed Stopper HSB

#Y206(CMD_WP := FALSE,

      FB_HP := NOT "A02 Y206 WP",

      FB_WP := "E02 Y206 WP",

      RLS := "E00 10F3 24V P02",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      VALV_WP => "A02 Y206 WP");

 

 

 

Netzwerk 21: Y207 Box Outfeed Stopper STC

#Y207(CMD_WP := FALSE,

      FB_HP := NOT "A02 Y207 WP",

      FB_WP := "E02 Y207 WP",

      RLS := "E00 10F3 24V P02",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      VALV_WP => "A02 Y207 WP");