FB30 MAIN P02 : Spring elasticity reading - main module program (slave 2) |
|
|
|
Netzwerk 1: P02 Initialisation
IF "M02 Init" OR NOT "M00 OB1 FirstCycle" THEN "M02 MW48" := #STEP_BITS := 0; IF "M02 Init" THEN "M02 MD40" := "M02 MD44" := 0; "M02 RunHomPos" := TRUE; "DatOfMod".P02.CrntModule := 102; END_IF; END_IF; |
|
|
|
Netzwerk 2: P02 SET execute home position
IF "M02 RunHomPos" AND #SET.SET.S.step0 THEN #SET.SET.S.steps := TRUE; END_IF;
IF NOT "M02 RunHomPos" OR "HMI KEY".SYS.GLB.F8_Stop OR "HMI KEY".P02.GLB.F8_Stop THEN #SET.SET.S.steps := "M02 RunHomPos" := FALSE; END_IF;
#SET.SET.S.steph := "M02 FLT ModuStp";
#SET(ACT_STEP => #SET.STEP_NO); |
|
|
|
Netzwerk 3: P02 SEQ1 start, stop, hold
#SEQ1.SSM1.S.steph := "M02 SEQ1 Start" AND NOT "M00 AutoCmpltMa run"; #SEQ1.SEQ1.S.steps := NOT "M02 RunHomPos" AND "M02 SEQ1 Start";
#SEQ1(ACT_STEP => #SEQ1.STEP_NO); |
|
|
|
Netzwerk 4: P02 FLT faults monitoring
#FLT(FLT_MODULE := "M02 FLT ModuStp"); |
|
|
|
Netzwerk 5: P02 STEP.SEQ1_Start
IF "M00 TrnsSysRun Imp" AND "M00 AutoCmpltMa run" THEN #STEP.SEQ1_Start := TRUE; RETURN; ELSIF #STEP.SEQ1_Start THEN IF NOT "M02 RunHomPos" AND NOT "M02 SEQ1 Active" THEN "M02 SEQ1 Start" := TRUE; ELSIF "M02 SEQ1 Active" THEN #STEP_BITS := 0; #STEP.SEQ1_Running := TRUE; #MaDa.RunTimeCntrl_seq1 := 0; "M02 SEQ1 WP1 DnOK" := "M02 SEQ1 DoWP1" := FALSE; END_IF; END_IF; |
|
|
|
Netzwerk 6: P02 STEP.SEQ1_Running
IF #STEP.SEQ1_Running THEN IF "M02 SEQ1 Done" THEN "M02 SEQ1 Active" := "M02 SEQ1 Start" := FALSE; #STEP_BITS := 0; #STEP.SEQ1_Done := TRUE; RETURN; END_IF; END_IF; |
|
|
|
Netzwerk 7: P02 STEP.Done
IF #STEP.SEQ1_Done THEN "M02 SEQ1 Done" := FALSE; #STEP_BITS := 0; #STEP.SEQ1_Write := TRUE; // Save actual data "DatOfMod".P02.STS.RunTimeCntr_seq1 := #MaDa.RunTimeCntr_seq1; "DatOfMod".P02.STS.WPC_ok := "M02 SEQ1 DoWP1" AND "M02 SEQ1 WP1 DnOK"; "DatOfMod".P02.STS.CrntWP_ok := "M02 SEQ1 WP1 DnOK" AND NOT "M02 SEQ1 WP1 DnNOK";
"DatOfMod".P02.TrgtModule := 102; // If necessary, changing drive direction to module 106 IF NOT "DatOfMod".P02.STS.CrntWP_ok THEN "DatOfMod".P02.TrgtModule := 106; END_IF; "DatOfPLC".P02 := "DatOfMod".P02; // Block move END_IF; |
|
|
|
Netzwerk 8: P02 STEP.Write
IF #STEP.SEQ1_Write THEN "M02 TCP/IP Wrt start" := TRUE;
IF "M02 TCP/IP Wrt done" THEN #STEP.SEQ1_Write := "M02 TCP/IP Wrt start" := "M02 TCP/IP Wrt done" := FALSE; END_IF; END_IF; |
|
|
|
Netzwerk 9: P02 Run-Time
IF #STEP.SEQ1_Running THEN IF "M00 Imp 10Hz" AND "M02 Enabled" THEN #MaDa.RunTimeCntr_seq1 := #MaDa.RunTimeCntr_seq1 + 1; END_IF; ELSE IF NOT "M02 Active" AND ("M00 ManuCmpltMa run" AND "HMI KEY".P02.GLB.F19_GoToStep OR "M00 AutoCmpltMa run") THEN #STEP.SEQ1_Start := TRUE; END_IF; END_IF; |
|
|
|
Netzwerk 10: P02 SEQ1 active
"M02 Active" := #STEP.SEQ1_Start AND "M02 SEQ1 Active" OR #STEP.SEQ1_Running OR #STEP.SEQ1_Done OR #STEP.SEQ1_Write; |
|
|
|
Netzwerk 11: P02 Assign signal
IF "M02 FLT ModuStpIS" THEN "M02 FLT ModuStpSR" := true; END_IF;
IF "M02 FLT ModuStpSR" AND NOT "M02 FLT ModuStp ACK" THEN IF "M00 ACK Imp" THEN "M02 FLT ModuStp ACK" := TRUE; END_IF; ELSIF NOT "M02 FLT ModuStpIS" AND "M02 FLT ModuStp ACK" THEN "M02 FLT ModuStpSR" := "M02 FLT ModuStp ACK" := FALSE; END_IF; #tmp_lamp_SigRD := "M02 FLT ModuStpSR" AND NOT "M02 FLT ModuStp ACK" AND "M00 Clock_1Hz" OR "M02 FLT ModuStpSR" AND "M02 FLT ModuStp ACK"; #tmp_lamp_SigGN := NOT "M02 FLT ModuStpSR" AND ("M00 AutoCmpltMa run" AND "M02 SEQ1 Active" OR "M00 Clock_1Hz" AND NOT "M00 AutoCmpltMa run" AND "M02 SEQ1 Active"); #tmp_lamp_SigYE := "M00 ManuCmpltMa run" AND "M00 Clock_1Hz" OR NOT "M00 AutoCmpltMa run" AND NOT "M00 ManuCmpltMa run";
|
|
FB41 SET P02: Spring elasticity reading - move to home position (slave 2)
|
|
|
|
Netzwerk 1: SET query home position "M02 HomPos" := "DI MAIN P02".SEQ1.Index = 0 AND "DI OUT P02".M5_Z.DRV.Support.HomDone AND "DI OUT P02".M5_Z.DRV.Support.InPos AND ("DI OUT P02".M5_Z.DRV.Support.ActPos = "DI OUT P02".MANUAL.M5_Z.Set_TchInPos_0 OR "DI OUT P02".M5_Z.DRV.Support.ActPos = "DI OUT P02".MANUAL.M5_Z.Set_TchInPos_1); // Pre-Setting "M02 MW48" := 0; |
|
|
|
Netzwerk 2: SET execute home position
#SET(MAX_STEP := 2); #ACT_STEP := #SET.S.stepact; #SET.S.DlyStart.PT := t#200ms; |
|
|
|
Netzwerk 3: Step jump distributor
CASE #SET.S.stepact OF 0: // Waiting for enable #SET.S.stepd :="DI OUT P02".M5_Z.DRV.Support.HomDone AND #SET.S.steps;
1: // Move M5_Z axis Elasticity servo drive HP IF #SET.S.stepfc THEN "DI OUT P02".M5_Z.DRV.MC_MoveAbsolute.Position := "DI OUT P02".MANUAL.M5_Z.Set_TchInPos_0; "DI OUT P02".M5_Z.DRV.Support.SetVelo := "DI OUT P02".MANUAL.M5_Z.Set_TchInVelo_0; RETURN; ELSE "M02 M5_Z GoToPosAbso" := NOT "DI OUT P02".M5_Z.HALT_01; END_IF; #SET.S.stepd := "DI OUT P02".M5_Z."MC MoveAbsolute".Done;
2: // Query module HP IF "DI OUT P02".HSC_FORC_IO.UserStatusFlags.StatusDQ0 AND "M02 HomPos" THEN "M02 RunHomPos" := FALSE; "M02 Enbl toRTT" := "DI MAIN P05".SEQ1.Shift_Register.%X8; END_IF; END_CASE; |
|