FB39 OUT P01 : Spring block reading - outputs (slave 1)

[hit  <- on your browser to return]

 

 

 

Netzwerk 1: Call manual operation

 

#MANUAL(ST_MANU := "M00 ManuCmpltMa run",

        MODULE_HP := "HMI KEY".P01.GLB.F20_HomPos,

        SUPPORT_SEQ := "M01 RunHomPos");

 

 

 

Netzwerk 2: Travel pre-setting

 

"HSC_TRAVEL"(SwGate := "M01 HSC OnOff",

             ErrorAck := "M00 ACK Imp",

             EventAck := FALSE,

             StatusHW => #HSC_TRVL_IO.OUT.StatusHW,

             StatusGate => #HSC_TRVL_IO.OUT.StatusGate,

             Error => #HSC_TRVL_IO.OUT.Error,

             MeasuredValue => #HSC_TRVL_IO.OUT.MeasuredValue,

             SetCountValue := #HSC_TRVL_IO.InOut.SetCountValue);

#HSC_TRVL_IO.UserStatusFlags.StatusDQ0 := "HSC_TRAVEL".UserStatusFlags.StatusDQ0;

#HSC_TRVL_IO.UserStatusFlags.StatusDQ1 := "HSC_TRAVEL".UserStatusFlags.StatusDQ1;

 

 

 

Netzwerk 3: Z01 Spring block slide

 

#Z01(CMD_WP := FALSE,

     CMD_HP := FALSE,

     FB_WP := "E01 Z01 WP",

     FB_HP := "E01 Z01 HP",

     RLS := "E00 Y56 WP",

     ACK_FLT := "M00 ACK Imp",

     VALV_WP => "A01 Z01 WP",

     VALV_HP => "A01 Z01 HP");