FB30 MAIN P01 : P01 Spring block reading - main module program (slave 1) |
|
|
|
Netzwerk 1: P01 Initialisation
IF "M01 Init" OR NOT "M00 OB1 FirstCycle" THEN "M01 MW38" := #STEP_BITS := 0; IF "M01 Init" THEN "M01 MD30" := "M01 MD34" := 0; "M01 RunHomPos" := TRUE; "DatOfMod".P01.CrntModule := 101; END_IF; END_IF; |
|
|
|
Netzwerk 2: P01 SET execute home position
IF "M01 RunHomPos" AND #SET.SET.S.step0 THEN #SET.SET.S.steps := TRUE; END_IF;
IF NOT "M01 RunHomPos" OR "HMI KEY".SYS.GLB.F8_Stop OR "HMI KEY".P01.GLB.F8_Stop THEN #SET.SET.S.steps := "M01 RunHomPos" := FALSE; END_IF;
#SET.SET.S.steph := "M01 FLT ModuStp";
#SET(ACT_STEP => #SET.STEP_NO); |
|
|
|
Netzwerk 3: P01 SEQ1 start, stop, hold
#SEQ1.SSM1.S.steph := "M01 SEQ1 Start" AND NOT "M01 AutoCompltMa run"; #SEQ1.SSM1.S.steps := NOT "M01 RunHomPos" AND "M01 SEQ1 Start";
#SEQ1(ACT_STEP => #SEQ1.STEP_NO); |
|
|
|
Netzwerk 4: P01 FLT faults monitoring
#FLT(FLT_MODULE := "M01 FLT ModuStp"); |
|
|
|
Netzwerk 5: P01 STEP.SEQ1_Start
IF "M00 TrnsSysRun Imp" AND "M00 AutoCmpltMa run" THEN #STEP.SEQ1_Start := TRUE; RETURN; ELSIF #STEP.SEQ1_Start THEN IF NOT "M01 RunHomPos" AND NOT "M01 SEQ1 Active" THEN "M01 SEQ1 Start" := TRUE; ELSIF "M01 SEQ1 Active" THEN #STEP_BITS := 0; #STEP.SEQ1_Running := TRUE; #MaDa.RunTimeCntrl_seq1 := 0; "M01 SEQ1 WP1 DnOK" := "M01 SEQ1 DoWP1" := FALSE; END_IF; END_IF; |
|
|
|
Netzwerk 6: P01 STEP.SEQ1_Running
IF #STEP.SEQ1_Running THEN IF "M01 SEQ1 Done" THEN "M01 SEQ1 Active" := "M01 SEQ1 Start" := FALSE; #STEP_BITS := 0; #STEP.SEQ1_Done := TRUE; RETURN; END_IF; END_IF; |
|
|
|
Netzwerk 7: P01 STEP.Done
IF #STEP.SEQ1_Done THEN "M01 SEQ1 Done" := FALSE; #STEP_BITS := 0; #STEP.SEQ1_Write := TRUE; // Save actual data "DatOfMod".P01.STS.RunTimeCntr_seq1 := #MaDa.RunTimeCntr_seq1; "DatOfMod".P01.STS.WPC_ok := "M01 SEQ1 DoWP1" AND "M01 SEQ1 WP1 DnOK"; "DatOfMod".P01.STS.CrntWP_ok := "M01 SEQ1 WP1 DnOK" AND NOT "M01 SEQ1 WP1 DnNOK";
"DatOfMod".P01.TrgtModule := 102; // If necessary, changing drive direction to module 106 IF NOT "DatOfMod".P01.STS.CrntWP_ok THEN "DatOfMod".P01.TrgtModule := 106; END_IF; "DatOfPLC".P01 := "DatOfMod".P01; // Block move END_IF; |
|
|
|
Netzwerk 8: P01 STEP.Write
IF #STEP.SEQ1_Write THEN "M01 TCP/IP Wrt start" := TRUE;
IF "M01 TCP/IP Wrt done" THEN #STEP.SEQ1_Write := "M01 TCP/IP Wrt start" := "M01 TCP/IP Wrt done" := FALSE; END_IF; END_IF; |
|
|
|
Netzwerk 9: P01 Run-Time
IF #STEP.SEQ1_Running THEN IF "M00 Imp 10Hz" AND "M01 Enabled" THEN #MaDa.RunTimeCntr_seq1 := #MaDa.RunTimeCntr_seq1 + 1; END_IF; ELSE IF NOT "M01 Active" AND ("M00 ManuCmpltMa run" AND "HMI KEY".P01.GLB.F19_GoToStep OR "M00 AutoCmpltMa run") THEN #STEP.SEQ1_Start := TRUE; END_IF; END_IF; |
|
|
|
Netzwerk 10: P01 SEQ1 active
"M01 Active" := #STEP.SEQ1_Start AND "M01 SEQ1 Active" OR #STEP.SEQ1_Running OR #STEP.SEQ1_Done OR #STEP.SEQ1_Write; |
|
|
|
Netzwerk 11: P01 Assign signal
IF "M01 FLT ModuStpIS" THEN "M01 FLT ModuStpSR" := true; END_IF;
IF "M01 FLT ModuStpSR" AND NOT "M01 FLT ModuStp ACK" THEN IF "M00 ACK Imp" THEN "M01 FLT ModuStp ACK" := TRUE; END_IF; ELSIF NOT "M01 FLT ModuStpIS" AND "M01 FLT ModuStp ACK" THEN "M01 FLT ModuStpSR" := "M01 FLT ModuStp ACK" := FALSE; END_IF; #tmp_lamp_SigRD := "M01 FLT ModuStpSR" AND NOT "M01 FLT ModuStp ACK" AND "M00 Clock_1Hz" OR "M01 FLT ModuStpSR" AND "M01 FLT ModuStp ACK"; #tmp_lamp_SigGN := NOT "M01 FLT ModuStpSR" AND ("M00 AutoCmpltMa run" AND "M01 SEQ1 Active" OR "M00 Clock_1Hz" AND NOT "M00 AutoCmpltMa run" AND "M01 SEQ1 Active"); #tmp_lamp_SigYE := "M00 ManuCmpltMa run" AND "M00 Clock_1Hz" OR NOT "M00 AutoCmpltMa run" AND NOT "M00 ManuCmpltMa run";
|
|
FB31 SET P01: Spring block reading - move to home position (slave 1)
|
|
|
|
Netzwerk 1: SET query home position "M01 HomPos" := "DI OUT P01".Z01.FB_HP AND "DI MAIN P01".SEQ1.Index = 0; // Pre-Setting "M01 MW38" := 0; |
|
|
|
Netzwerk 2: SET execute home position
#SET(MAX_STEP := 2); #ACT_STEP := #SET.S.stepact; #SET.S.DlyStart.PT := t#200ms; |
|
|
|
Netzwerk 3: Step jump distributor
CASE #SET.S.stepact OF 0: // Waiting for enable #SET.S.stepd := #SET.S.steps;
1: // Z01 Spring-block slide HP "DI MAIN P01".SEQ1.Index := 0;
"DI OUT P01".Z01.VLV.CmdExe_WP := FALSE; "DI OUT P01".Z01.VLV.CmdExe_HP := "HMI KEY".P01.Z01.F11_Enable_HP; #SET.S.stepd := "DI OUT P01".Z01.FB_HP;
2: // Query travel measuring sensor zero point IF "DI OUT P01".HSC_TRVL_IO.UserStatusFlags.StatusDQ0 AND "M01 HomPos" THEN "M01 RunHomPos" := FALSE; "M01 Enbl toRTT" := "DI MAIN P05".SEQ1.Shift_Register.%X3; END_IF; END_CASE; |
|