Netzwerk 1: Call manual operation

#Manual(ST_MANU := "DI MAIN GLB".M00.ManuCmpltMa_run,

        MODULE_HP := "HMI KEY".P02.GLB.F20_HomPos,

        SUPPORT_SEQ := "DI MAIN P02".M00.HomPosRun);

 

 

 

Netzwerk 2: Pre-Setting

#Support.Estop_TOF(IN := "DI MAIN GLB".M00.GLB_Estop,

                   PT := t#1s);

#tmp_operation_mode := "DI MAIN GLB".M00.AutoCmpltMa_run OR "DI MAIN P02".M00.HomPosRun OR "DI MAIN P02".SEQ1.SSM.S.stepin;

 

 

 

Netzwerk 3: RV100_PAW Input Heating Oil Regulating Valve

#RV200_PAW(REQ_VALUE := #RV200_PID.Output,

           H_LIM := 100.0,

           L_LIM := 0.0,

           PAW_OUT => "A00 RV100_PAW":P);

 

 

 

Netzwerk 4: V200 Heating Oil Shut-Off Valve

#V200(CMD_WP := FALSE,

      FB_HP := "E00 V200 CLS",

      FB_WP := "E00 V200 OPN",

      RLS := TRUE,

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      VALV_WP => "A00 V200 OPN");

 

 

 

Netzwerk 5: T200_PEW Input Heating Oil temperature 3-170°C

#T200_PEW(PEW_IN := "E00 T200_PEW":P,

          H_LIM := #T200_PEW.Support.High_Lim,

          L_LIM := #T200_PEW.Support.Low_Lim,

          PEW_SCALE := #T200_PEW.Support.PEW_Scaled);

 

 

 

Netzwerk 6: T201_PEW Output Heating Oil temperature 3-145°C

#T201_PEW(PEW_IN := "E00 T201_PEW":P,

          H_LIM := #T201_PEW.Support.High_Lim,

          L_LIM := #T201_PEW.Support.Low_Lim,

          PEW_SCALE := #T201_PEW.Support.PEW_Scaled);

 

 

 

Netzwerk 7: M200 Oil Circulating pump

#M200(CMD_ONOFF := FALSE,

      FD_BACK := "E00 M200 FdBk",

      MCB := "E00 M200 MCB",

      HALT_01 := NOT "E00 Estop OK",

      ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp,

      MOT_CW => "A00 M200 WP");