FB49 OUT P02 : Non Pneumatic Tires heating oil assign output stage |
|
|
|
Netzwerk 1: Call manual operation #Manual(ST_MANU := "DI MAIN GLB".M00.ManuCmpltMa_run, MODULE_HP := "HMI KEY".P02.GLB.F20_HomPos, SUPPORT_SEQ := "DI MAIN P02".M00.HomPosRun); |
|
|
|
Netzwerk 2: Pre-Setting #Support.Estop_TOF(IN := "DI MAIN GLB".M00.GLB_Estop, PT := t#1s); #tmp_operation_mode := "DI MAIN GLB".M00.AutoCmpltMa_run OR "DI MAIN P02".M00.HomPosRun OR "DI MAIN P02".SEQ1.SSM.S.stepin; |
|
|
|
Netzwerk 3: RV100_PAW Input Heating Oil Regulating Valve #RV200_PAW(REQ_VALUE := #RV200_PID.Output, H_LIM := 100.0, L_LIM := 0.0, PAW_OUT => "A00 RV100_PAW":P); |
|
|
|
Netzwerk 4: V200 Heating Oil Shut-Off Valve #V200(CMD_WP := FALSE, FB_HP := "E00 V200 CLS", FB_WP := "E00 V200 OPN", RLS := TRUE, ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, VALV_WP => "A00 V200 OPN"); |
|
|
|
Netzwerk 5: T200_PEW Input Heating Oil temperature 3-170°C #T200_PEW(PEW_IN := "E00 T200_PEW":P, H_LIM := #T200_PEW.Support.High_Lim, L_LIM := #T200_PEW.Support.Low_Lim, PEW_SCALE := #T200_PEW.Support.PEW_Scaled); |
|
|
|
Netzwerk 6: T201_PEW Output Heating Oil temperature 3-145°C #T201_PEW(PEW_IN := "E00 T201_PEW":P, H_LIM := #T201_PEW.Support.High_Lim, L_LIM := #T201_PEW.Support.Low_Lim, PEW_SCALE := #T201_PEW.Support.PEW_Scaled); |
|
|
|
Netzwerk 7: M200 Oil Circulating pump #M200(CMD_ONOFF := FALSE, FD_BACK := "E00 M200 FdBk", MCB := "E00 M200 MCB", HALT_01 := NOT "E00 Estop OK", ACK_FLT := "DI MAIN GLB".M00.FLT_CmpltMaACK_Imp, MOT_CW => "A00 M200 WP"); |
|