OB1 Main

 

 

 

Netzwerk 3: Switch off all driver when manual ON->OFF

O "M00 ST Manu CmpltMa run"

O "M00 ST PLC FrsCyclePuls"

FN "M00 ST PLC FrsCycle FN"

SPBN m004

CALL "FC INIT S10"

BEA

 

 

 

Netzwerk 4: CALL distributor

m004: CALL "FB HMI S10", "DI ST HMI" // know how protected

CALL "FB MAIN S10", "DI MAIN S10" // see right side

-> CALL "FB MAIN P01", "DI MAIN P01"

-> CALL "FB MAIN P04", "DI MAIN P04"

-> CALL "FB MAIN P06", "DI MAIN P06"

-> CALL "FB MAIN P07", "DI MAIN P07"

 

CALL "FB OUT S10", "DI OUT S10" // hit MaPa button

CALL "FB OUT P01", "DI OUT P01" // hit MaPa button

CALL "FB OUT P04", "DI OUT P04" // hit MaPa button

CALL "FB OUT P06", "DI OUT P06" // hit MaPa button

 

 

 

Netzwerk 5: Impulse/Pulse first OB cycle

UN "M00 ST PLC FirstCycle"

L s5t#1s

SV "T00 ST PLC FirstCycleSV"

U "T00 ST PLC FirstCycleSV"

= "M00 ST PLC FrsCyclePuls"

 

U "M00 log 1"

L s5t#2s

SE "T00 ST PLC FirstCycle"

U "T00 ST PLC FirstCycle"

= "M00 ST PLC FirstCycle"

 

 

 

Netzwerk 6: Flag logic =0/1

U "M00 log 0"

R "M00 log 0"

SET

= "M00 log 1"

 

FB20 MAIN S10 : Station Operation Modes

 

 

 

Netzwerk 1: Fault acknowledgement

O "HMI KEY".S10.F1_AckKey

O "M00 ST PLC FrsCyclePuls"

FP "M00 ST ACK FP"

= "M00 ST ACK Imp"

 

 

 

Netzwerk 2: Call main station safety program

CALL "Main_Safety_FB21", "Main_Safety_DB21"

 

 

 

Netzwerk 3: Safety door opened HMI

O "Main_Safety_DB21"."T00 ST OpnSftyDr 1".Q

O "Main_Safety_DB21"."T00 ST OpnSftyDr 2".Q

= "HMI KEY".ST30.F10_Open_SafetyDoor_HMI

 

 

 

Netzwerk 4: Station error evaluation

CALL #FLT

FLT_ACK :="M00 ST ACK Imp"

IMP_100MS :="M00 Imp 10Hz"

FLT_MODULE :="M00 ST FltCmpltMaIST"

 

 

 

Netzwerk 5: Faults (red lamp)

U "M00 ST FltCmpltMaIST"

S "M00 ST FltCmpltMaSET"

 

UN "M00 ST FltCmpltMaSET"

UN "M00 ST Flt ACK"

SPB m001

U "M00 ST FltCmpltMaSET"

U "M00 ST ACK Imp"

S "M00 ST Flt ACK"

UN "M00 ST FltCmpltMaIST"

U "M00 ST Flt ACK"

R "M00 ST FltCmpltMaSET"

R "M00 ST Flt ACK"

m001: U "M00 ST FltCmpltMaSET"

UN "M00 ST Flt ACK"

U "Clock_0.5Hz"

O

U "M00 ST FltCmpltMaSET"

U "M00 ST Flt ACK"

= "A00 H10 FLT lamp"

 

 

 

Netzwerk 6: Lack of parts light (yelow lamp)

U "M00 ST AutoCmpltMa run"

= "A00 H11 PartLck lamp"

 

 

 

Netzwerk 7: Control 4M2 outlet conveyor

U "M00 ST AutoCmpltMa run"

= "A00 H12 Auto lamp"

 

 

 

Netzwerk 8: Automatic (green lamp)

U "M01 HomPos"

U "M04 HomPos"

U "M06 HomPos"

U "M07 HomPos"

= "M00 ST HomPos"

S "M00 HomPos"

 

O "M00 ST FltCmpltMaSET"

O #SET.S.steps

R "M00 HomPos"

 

 

 

Netzwerk 9: Start operating mode 'automatic'

O "M00 ST HomPos"

O "M00 HomPos"

U "HMI KEY".S10.F3_OM_AUTO_ON

S "M00 ST OM AUTO"

R "M00 ST OM MANUAL"

R "M00 ST OM HOME POS"

R "M00 ST Manu CmpltMa run"

 

O "M00 HomPos"

O "M00 ST Enbl run-down"

U "E00 2S1 Start"

U "M00 ST OM AUTO"

S "M00 ST AutoCmpltMa run"

 

O "M00 ST AutoCmpltMa run"

FP "M00 ST TrnsSysRun FP"

= "M00 ST TrnsSysRun Imp"

 

 

 

Netzwerk 10: Start operating mode 'run-down'

 

 

 

 

Netzwerk 11: Start operating mode 'manual'

U "HMI KEY".S10.F4_OM_MANU_ON

S "M00 ST OM MANUAL"

R "M00 ST OM AUTO"

R "M00 ST AutoCmpltMa run"

R "M00 ST OM HOME POS"

 

U "HMI KEY".S10.F5_Start

U "M00 ST OM MANUAL"

S "M00 ST Manu CmpltMa run"

 

 

 

Netzwerk 12: Start "home position" complete machine

U "HMI KEY".S10.F7_OM_HOM_POS_ON

UN "M00 ST HomPos"

S "M00 ST OM HOME POS"

R "M00 ST OM AUTO"

R "M00 ST OM MANUAL"

R "M00 ST Manu CmpltMa run"// mc24.08

 

U "HMI KEY".S10.F5_Start

U "M00 ST OM HOME POS"

UN "M00 ST FltCmpltMaSET"

U #SET.S.S0

S #SET.S.steps

 

ON "M00 ST OM HOME POS"

O "HMI KEY".S10.F8_Stop

R #SET.S.steps

 

U "M00 ST FltCmpltMaSET"

= #SET.S.steph

 

CALL #SET

ADR :=0

FC_NO :=20

 

 

 

Netzwerk 13: Stop all operating mode

O "M00 ST FltCmpltMaSET"

ON "E00 2S2 Stop"

R "M00 ST AutoCmpltMa run"

 

U "M00 ST Manu CmpltMa run"

U "HMI KEY".S10.F8_Stop

R "M00 ST Manu CmpltMa run"

 

 

 

Netzwerk 14: Common start of synchronized sequencer

 

 

 

 

Netzwerk 15: Show key colour on HMI

O "M00 ST Manu CmpltMa run"

O #SET.S.steps

= "HMI KEY".S10.Show_KeyColour

 

O "M00 ST OM MANUAL"

O "M00 ST OM HOME POS"

= "HMI KEY".S10.Show_Key

 

 

 

Netzwerk 16: Enable selective run of assembly module

LAR1 P##Module_No

L ''

T D [ AR1 , P#0.0 ]

L #HMI_Module_No

+AR1

U "M00 ST OM MANUAL"

= DIX [ AR1 , P#0.0 ]

 

 

 

Netzwerk 17: Inching complete machine (Option)

U "HMI KEY".S10.F2_InchCmpltMa

FP "M00 ST InchCmpltMa FP"

U #Module_No[31]

= "M00 ST InchCmpltMa Imp"

 

 

 

Netzwerk 18: Enable running of assembly module

O #Module_No[1]

O "M00 ST InchCmpltMa Imp"

O "M00 ST AutoCmpltMa run"

= "M01 Enabled"

 

O #Module_No[4]

O "M00 ST InchCmpltMa Imp"

O "M00 ST AutoCmpltMa run"

= "M04 Enabled"

 

O #Module_No[6]

O "M00 ST InchCmpltMa Imp"

O "M00 ST AutoCmpltMa run"

= "M06 Enabled"

 

O #Module_No[7]

O "M00 ST InchCmpltMa Imp"

O "M00 ST AutoCmpltMa run"

= "M07 Enabled"

 

To go to next HMI image use the touch buttons; some of them are interactive.