FB68 MAN P04 : Spring winding point inspection - manual mode (slave 4) |
|
|
|
Netzwerk 1: G04 Clamp cylinder enable
"HMI KEY".P04.G04.F11_Enable_HP := "HMI KEY".P04.G04.F12_Enable_WP := "DI OUT P04".G04.VLV.SetIdleTime > 0 AND "E00 Y56 WP" AND NOT "DI OUT P04".G04.vlv_com_flt; |
|
|
|
Netzwerk 2: Z05 Rotary cylinder enable
"HMI KEY".P04.Z05.F11_Enable_HP := "HMI KEY".P04.Z05.F12_Enable_WP := "DI OUT P04".Z05.VLV.SetIdleTime > 0 AND "E00 Y56 WP" AND NOT "DI OUT P04".Z05.vlv_com_flt; |
|
|
|
Netzwerk 3: Z06 Lift cylinder enable
"HMI KEY".P04.Z06.F11_Enable_HP := "HMI KEY".P04.Z06.F12_Enable_WP := "DI OUT P04".Z06.VLV.SetIdleTime > 0 AND "E00 Y56 WP" AND NOT "DI OUT P04".Z06.vlv_com_flt; |
|
|
|
Netzwerk 4: Z07 Lift lock-out cylinder enable
"HMI KEY".P04.Z07.F11_Enable_HP := "HMI KEY".P04.Z07.F12_Enable_WP := "DI OUT P04".Z07.VLV.SetIdleTime > 0 AND "E00 Y56 WP" AND NOT "DI OUT P04".Z07.vlv_com_flt |
|
|
|
Netzwerk 5: Monitoring manual operation ***
IF NOT #ST_MANU THEN RETURN; ELSIF #MODULE_HP AND NOT #GLB.HomPos_REg THEN "M04 Init" := TRUE; END_IF; #GLB.HomPos_REg := #MODULE_HP; IF #SUPPORT_SEQ THEN RETURN; END_IF; |
|
|
|
Netzwerk 6: G04 Clamp cylinder execute
"DI OUT P04".G04.VLV.CmdExe_WP := "HMI KEY".P04.G04.F12_Enable_WP AND NOT "HMI KEY".P04.G04.F1_HP AND ("HMI KEY".P04.G04.F2_WP OR "DI OUT P04".G04.FB_WP);
"DI OUT P04".G04.VLV.CmdExe_HP := "HMI KEY".P04.G04.F11_Enable_HP AND NOT "HMI KEY".P04.G04.F2_WP AND ("HMI KEY".P04.G04.F1_HP OR "DI OUT P04".G04.FB_HP); |
|
|
|
Netzwerk 7: Z05 Rotary cylinder execute
"DI OUT P04".Z05.VLV.CmdExe_WP := "HMI KEY".P04.Z05.F12_Enable_WP AND NOT "HMI KEY".P04.Z05.F1_HP AND ("HMI KEY".P04.Z05.F2_WP OR "DI OUT P04".Z05.FB_WP);
"DI OUT P04".Z05.VLV.CmdExe_HP := "HMI KEY".P04.Z05.F11_Enable_HP AND NOT "HMI KEY".P04.Z05.F2_WP AND ("HMI KEY".P04.Z05.F1_HP OR "DI OUT P04".Z05.FB_HP); |
|
|
|
Netzwerk 8: Z06 Lift cylinder execute
"DI OUT P04".Z06.VLV.CmdExe_WP := "HMI KEY".P04.Z06.F12_Enable_WP AND NOT "HMI KEY".P04.Z06.F1_HP AND ("HMI KEY".P04.Z06.F2_WP OR "DI OUT P04".Z06.FB_WP);
"DI OUT P04".Z06.VLV.CmdExe_HP := "HMI KEY".P04.Z06.F11_Enable_HP AND NOT "HMI KEY".P04.Z06.F2_WP AND ("HMI KEY".P04.Z06.F1_HP OR "DI OUT P04".Z06.FB_HP); |
|
|
|
Netzwerk 9: Z07 Lift lock-out cylinder execute
"DI OUT P04".Z07.VLV.CmdExe_WP := "HMI KEY".P04.Z07.F12_Enable_WP AND NOT "HMI KEY".P04.Z07.F1_HP AND ("HMI KEY".P04.Z07.F2_WP OR "DI OUT P04".Z07.FB_WP);
"DI OUT P04".Z07.VLV.CmdExe_HP := "HMI KEY".P04.Z07.F11_Enable_HP AND NOT "HMI KEY".P04.Z07.F2_WP AND ("HMI KEY".P04.Z07.F1_HP OR "DI OUT P04".Z07.FB_HP); |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|