FB68 MAN P04 Spring winding point inspection - manual mode (slave 4)

 

 

 

Netzwerk 1: G04 Clamp cylinder enable

 

"HMI KEY".P04.G04.F11_Enable_HP := "HMI KEY".P04.G04.F12_Enable_WP :=

"DI OUT P04".G04.VLV.SetIdleTime > 0

AND "E00 Y56 WP" AND NOT "DI OUT P04".G04.vlv_com_flt;

 

 

 

Netzwerk 2: Z05 Rotary cylinder enable

 

"HMI KEY".P04.Z05.F11_Enable_HP := "HMI KEY".P04.Z05.F12_Enable_WP :=

"DI OUT P04".Z05.VLV.SetIdleTime > 0

AND "E00 Y56 WP" AND NOT "DI OUT P04".Z05.vlv_com_flt;

 

 

 

Netzwerk 3: Z06 Lift cylinder enable

 

"HMI KEY".P04.Z06.F11_Enable_HP := "HMI KEY".P04.Z06.F12_Enable_WP :=

"DI OUT P04".Z06.VLV.SetIdleTime > 0

AND "E00 Y56 WP" AND NOT "DI OUT P04".Z06.vlv_com_flt;

 

 

 

Netzwerk 4: Z07 Lift lock-out cylinder enable

 

"HMI KEY".P04.Z07.F11_Enable_HP := "HMI KEY".P04.Z07.F12_Enable_WP :=

"DI OUT P04".Z07.VLV.SetIdleTime > 0

AND "E00 Y56 WP" AND NOT "DI OUT P04".Z07.vlv_com_flt

 

 

 

Netzwerk 5: Monitoring manual operation ***

 

IF NOT #ST_MANU THEN

    RETURN;

ELSIF #MODULE_HP AND NOT #GLB.HomPos_REg THEN

   "M04 Init" := TRUE;

END_IF;

#GLB.HomPos_REg := #MODULE_HP;

IF #SUPPORT_SEQ THEN

    RETURN;

END_IF;

 

 

 

Netzwerk 6: G04 Clamp cylinder execute

 

"DI OUT P04".G04.VLV.CmdExe_WP := "HMI KEY".P04.G04.F12_Enable_WP

AND NOT "HMI KEY".P04.G04.F1_HP AND ("HMI KEY".P04.G04.F2_WP OR "DI OUT P04".G04.FB_WP);

 

"DI OUT P04".G04.VLV.CmdExe_HP := "HMI KEY".P04.G04.F11_Enable_HP

AND NOT "HMI KEY".P04.G04.F2_WP AND ("HMI KEY".P04.G04.F1_HP OR "DI OUT P04".G04.FB_HP);

 

 

 

Netzwerk 7: Z05 Rotary cylinder execute

 

"DI OUT P04".Z05.VLV.CmdExe_WP := "HMI KEY".P04.Z05.F12_Enable_WP

AND NOT "HMI KEY".P04.Z05.F1_HP AND ("HMI KEY".P04.Z05.F2_WP OR "DI OUT P04".Z05.FB_WP);

 

"DI OUT P04".Z05.VLV.CmdExe_HP := "HMI KEY".P04.Z05.F11_Enable_HP

AND NOT "HMI KEY".P04.Z05.F2_WP AND ("HMI KEY".P04.Z05.F1_HP OR "DI OUT P04".Z05.FB_HP);

 

 

 

Netzwerk 8: Z06 Lift cylinder execute

 

"DI OUT P04".Z06.VLV.CmdExe_WP := "HMI KEY".P04.Z06.F12_Enable_WP

AND NOT "HMI KEY".P04.Z06.F1_HP AND ("HMI KEY".P04.Z06.F2_WP OR "DI OUT P04".Z06.FB_WP);

 

"DI OUT P04".Z06.VLV.CmdExe_HP := "HMI KEY".P04.Z06.F11_Enable_HP

AND NOT "HMI KEY".P04.Z06.F2_WP AND ("HMI KEY".P04.Z06.F1_HP OR "DI OUT P04".Z06.FB_HP);

 

 

 

Netzwerk 9: Z07 Lift lock-out cylinder execute

 

"DI OUT P04".Z07.VLV.CmdExe_WP := "HMI KEY".P04.Z07.F12_Enable_WP

AND NOT "HMI KEY".P04.Z07.F1_HP AND ("HMI KEY".P04.Z07.F2_WP OR "DI OUT P04".Z07.FB_WP);

 

"DI OUT P04".Z07.VLV.CmdExe_HP := "HMI KEY".P04.Z07.F11_Enable_HP

AND NOT "HMI KEY".P04.Z07.F2_WP AND ("HMI KEY".P04.Z07.F1_HP OR "DI OUT P04".Z07.FB_HP);

 

 